25 kVA / 125 kVA
Compact Design
Mahindra Powerol diesel gensets have the capability to switch seamlessly to backup power due to its compact design & swift recovery. Also, voltage fluctuations are never an issue as our effective governing system controls ensure complete safety of your equipment.
Large Fuel Tank
With one of the most popular engines in its category, the Mahindra Powerol Engine fitted in this genset, it has one of the smallest footprints with high capacity fuel tanks in comparison to other gensets. It also has minimum vibrations and is very stable.
Longer Engine Life
All the stringent noise & emission norms stipulated by the Central Pollution Control Board of India (CPCB) are strictly followed by all Powerol DG Sets. All our engines are regularly tested on various applications for efficiency and performance in accordance to our promise of quality of the highest order.
Low Maintenance Cost
With the might of the whole Mahindra machinery at our disposal, our gensets come equipped with an Annual Maintenance Contract (AMC) and are the most fuel efficient in their class along with having very low operational costs. Our main USP is that we offer Zero-Leak engines with manual as well as AMF Control Panel Options available.
Preferred By All
Our gensets find application in industries like Telecom, Defence & the Railway Sector as well as Petrol Pumps, Hospitals, Super Markets, Banks & Construction Sites. Our presence in myriad applications speaks volumes about the quality of our products and the efficiency with which we deliver.
Assurance
- Over 400 sales and service touch points.
- Easy Finance schemes available.
- Fuel Efficient Engines.
Technical Specifications
- PARAMETERS DG MODELS
- Genset Prime Rating (kVA) *25
- Duty (Standby/ Prime)Prime
- Power Rating @ 100% kWe (in KW)20
- No. of Phases1 Ph / 3 Ph
- Output Voltage (V)230 / 415
- Power Factor (lagging)0.8
- Current (A)108.7 / 34.8
- Frequency (Hz) & RPM50/1500
- Governing ClassG2 as per ISO 8528 part 5
- Genset dimensions (L x W x H) in mm2285 X 1030 X 1255
- Genset Weight (Kg) Approx.865
- Engine SpecificationDG MODELS
- MakeMahindra
- Power Output# (Kw)26.8
- AspirationNA
- No. of cylinders4
- Bore x Stroke (mm)88.9 x 101.6
- Displacement (Lit)2523
- Fuel consumption @ 75% load (kg/hr) **4
- Fuel consumption @ 100% load (kg/hr)**5
- Starting system12 V DC Electrical
- Lube oil specificationMaximile CNG Plus
- Total lubrication system capacity7
- Lube oil consumption @ full load$0.15% of FC
- Lube oil change period (hrs.) 500
- Radiator coolant capacity (liter)10
- Alternator DG MODELS
- MakeCG/LS
- Enclosure TypeIP 23
- Voltage regulation+/- 1% with 4% engine Governing
- Class of insulationClass H
- Maximum Unbalanced Load across Phases25%
- PARAMETERS DG MODELS
- Genset Prime Rating (kVA) *125
- Duty (Standby/ Prime)Prime
- Power Rating @ 100% kWe (in KW)100
- No. of Phases3 Phase
- Output Voltage (V)415V
- Power Factor (lagging)0.8
- Current (A)174
- Frequency (Hz) & RPM50/1500
- Governing ClassG2 as per ISO 8528 part 5
- Genset dimensions (L x W x H) in mm3750 x 1300 x 1700
- Genset Weight (Kg) Approx.2250
- Engine SpecificationDG MODELS
- MakeMahindra
- Power Output# (Kw)114.7
- AspirationTCI
- No. of cylinders6
- Bore x Stroke (mm)105 x 137
- Displacement (Lit)7118
- Fuel consumption @ 75% load (kg/hr) **20
- Fuel consumption @ 100% load (kg/hr)**25
- Starting system24 V DC Electrical
- Lube oil specificationMaximile CNG Plus
- Total lubrication system capacity20.2 Ltr
- Lube oil consumption @ full load$0.15% of FC
- Lube oil change period (hrs.) 500
- Radiator coolant capacity (liter)24
- Alternator DG MODELS
- MakeCG/LS
- Enclosure TypeIP 23
- Voltage regulation+/- 1% with 4% engine Governing
- Class of insulationClass H
- Maximum Unbalanced Load across Phases25%