10 kVA / 15 kVA
It has the capability to switch seamlessly to backup power due to its compact design & swift recovery. Also, voltage fluctuations are never an issue as our effective governing system controls ensure complete safety of your equipment.
With one of the most popular engines in its category, the Mahindra Powerol Engine fitted in this genset, it has one of the smallest footprints with high capacity fuel tanks in comparison to other gensets. It also has minimum vibrations and is very stable.
All the stringent noise & emission norms stipulated by the Central Pollution Control Board of India (CPCB) are strictly followed by all Powerol DG Sets. All our engines are regularly tested on various applications for efficiency and performance in accordance to our promise of quality of the highest order.
With the might of the whole Mahindra machinery at our disposal, our gensets come equipped with an Annual Maintenance Contract (AMC) and are the most fuel efficient in their class along with having very low operational costs. Our main USP is that we offer Zero-Leak engines with manual as well as AMF Control Panel Options available.
Our gensets find application in industries like Telecom, Defence & the Railway Sector as well as Petrol Pumps, Hospitals, Super Markets, Banks & Construction Sites. Our presence in myriad applications speaks volumes about the quality of our products and the efficiency with which we deliver.
Assurance
- Over 400 sales and service touch points.
- Easy Finance schemes available.
- Fuel Efficient Engines.
Technical Specifications
- PARAMETERS DG Models
- Duty (Standby/ Prime)Prime
- 50 HZ PRIME :-
- Rating(kVA) 10 kVA
- Rated(kWe) 8
- Rating(kVA) 2185GM-C2
- No of Cylinders2
- No of Phases 1/3
- Output Voltage (V) 230/415
- Power Factor (lagging)0.8
- Current (A) (1Phase / 3Phase) 43.5/13.9
- Frequency (Hz)/ RPM 50/1500
- Governing classA1
- Fuel tank capacity 55
- Genset Dimension (LxWxH $$) (mm) Approx. 1700 X 900 X 1250
- Genset Weight (Kg), Appx633
- Engine Specification DG Models
- Make / Series Mahindra mPower
- Power Output# (HP)18
- Aspiration Naturally Aspirated
- Bore x Stroke (mm) 88.9 x 110
- Displacement (Lit) 1366
- Fuel consumption @ 75% load (lit/hr) ^ 2.4
- Fuel consumption @ 100% load (lit/hr) ^2.9
- Lube oil specificationSAE15W40 CH4
- Total lubrication system capacity (lit) 6
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
- Lube oil change period (hrs.)300 hrs. for Oil Top Up, 600 hrs. for Oil change
- Governing classA1
- Radiator coolant capacity (liter)5.5
- AlternatorDG Models
- Make CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%
- PARAMETERS DG Models
- Duty (Standby/ Prime)Stand By Prime
- 50 HZ PRIME :-
- Rating(kVA) 15 kVA15 kVA
- Rated(kWe) 1212
- Rating(kVA) 2205 GM C23255 GM C2
- No of Cylinders23
- No of Phases 1/31/3
- Output Voltage (V) 230/415 230/415
- Power Factor (lagging)0.80.8
- Current (A) (1Phase / 3Phase) 65.2/20.9 65.2/20.9
- Frequency (Hz)/ RPM 50/150050/1500
- Governing classA1A1
- Starting system 12 V DC electrical 12 V DC electrical
- Fuel tank capacity 5575
- Genset Dimension (LxWxH $$) (mm) Approx. 1700 X 900 X 12501875 X 900 X 1287
- Genset Weight (Kg), Appx673673
- Engine Specification DG Models
- Make / Series Mahindra mPower
- Power Output# (HP)20 25
- Aspiration Naturally AspiratedNaturally Aspirated
- Bore x Stroke (mm) 88.9 X 120 88.9 X 110
- Displacement (Lit) 14902048
- Fuel consumption @ 75% load (lit/hr) ^ 2.7 3
- Fuel consumption @ 100% load (lit/hr) ^3.6 3.8
- Lube oil specificationSAE15W40 CH4SAE15W40 CH4
- Total lubrication system capacity (lit) 615 kVA
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption0.15% of Fuel Consumption
- Lube oil change period (hrs.)300 hrs. for Oil Top Up 600 hrs. for Oil change300 hrs. for Oil Top Up 600 hrs. for Oil change
- Governing classA115 kVA
- Radiator coolant capacity (liter)5.55.5
- AlternatorDG Models
- Make CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%